HRS DF1B-2022SC
Product Overview
This product is designed for electrical connections, offering reliable performance within specified voltage and current ratings. It is suitable for applications requiring stable connections under varying environmental conditions.
Technical Specifications
| Item | Test Method | Requirements | QT | AT |
|---|---|---|---|---|
| Contact Resistance | Millivolt Level Method (100 mA (DC or 1000Hz)) | 30 m MAX. | X | |
| Contact Insertion Force | 0.6350.002mm by Steel Gauge | 4.4 N MAX. | X | |
| Contact Extraction Force | 0.6350.002mm by Steel Gauge | 0.44 N MIN. | X | |
| Mechanical Operation (30 Cycles) | 30 Insertions and Extractions | 1. Contact Resistance: 30 m MAX. 2. No Damage, Crack or Looseness of Parts. | X | |
| Vibration | 10 to 55 Hz, Single Amplitude 0.75 mm, at 2 h, for 3 Directions | 1. No Electrical Discontinuity of 1 s. 2. No Damage, Crack or Looseness of Parts. | X | |
| Shock | 490 m/s, Duration of Pulse 11 ms at 3 Times for 3 Directions | No Damage, Crack or Looseness of Parts. | X | |
| Rapid Change of Temperature | 555 to 35+855 to35 C, Time 305305 min, Under 5 Cycles | 1. Contact Resistance: 30 m MAX. 2. No Damage, Crack or Looseness of Parts. | X | |
| Damp Heat (Steady State) | 40 2 C, 90 to 95 %, 96 h | 1. Contact Resistance: 30 m MAX. 2. No Damage, Crack or Looseness of Parts. | X |
General Ratings
| Rating | Value |
|---|---|
| Voltage | 250 V AC /DC |
| Current (AWG20) | 5 A |
| Current (AWG22) | 3 A |
| Operating Temperature Range | -35 C to +85 C (Note 1) |
| Storage Temperature Range | -10 C to +60 C (Note 3) |
| Operating Humidity Range | 40% to +80% (Note 2) |
| Storage Humidity Range | 40% to +70% (Note 3) |
Remarks:
Note 1: Including the temperature rising by current.
Note 2: No condensing.
Note 3: Apply to the condition of long term storage for unused products before mounted on PCB. After mounted on PCB, operating temperature and humidity range is applied for interim storage during transportation.