EATON 16593-2
Bussmann Series UL Recognized Power Distribution Blocks
Bussmann series UL Recognized power distribution blocks provide versatile lineside and loadside port configurations for enhanced panel wiring and wire management. These blocks are UL Recognized to UL 1059 and suitable for use in UL 508A industrial control panels. Available in 1-, 2-, and 3-pole versions, with optional covers for added safety (sold separately). Catalog numbers are structured with a prefix defining block characteristics and a suffix indicating the number of poles.
Product Attributes
- Brand: Bussmann
- Certifications: UL Recognized (UL 1059, Guide XCFR2, File E62622), CSA Certified (Class 6228-01, File 15364)
- Flammability Rating: UL 94 V0
Technical Specifications
| Catalog Number | No. of Poles | Current Rating (A) | Lineside Wire Size (Cu/Al) | Lineside Ports/Pole | Loadside Wire Size (Cu/Al) | Loadside Ports/Pole | Max SCCR (kA) |
|---|---|---|---|---|---|---|---|
| 16021-_ | 2, 3, 4 | 175 | 2/0 - #1 (Str) | 1 | #4 - #6 (Str) | 1 | 10 |
| 16220-_ | 1, 2, 3 | 175 | 2/0 - #1 (Str) | 1 | #4 - #6 (Str) | 1 | 200 |
| 16220-_H | 1, 2, 3 | 175 | 2/0 - #1 (Str) | 1 | #4 - #6 (Str) | 1 | 200 |
| 16321-_ | 1, 2, 3 | 175 | 2/0 - #1 (Str) | 1 | #4 - #6 (Str) | 1 | 200 |
| 16023-_ | 2, 3, 4 | 310 | 350kcmil - 2/0 (Str) | 1 | #4 - #6 (Str) | 1 | 10 |
| 16323-_ | 1, 2, 3 | 310 | 350kcmil - 2/0 (Str) | 1 | #4 - #6 (Str) | 1 | 200 |
| 16332-_ | 1, 2, 3 | 310 | 350kcmil - 2/0 (Str) | 1 | #2 - #3 (Str) | 1 | 10 |
| 16370-_ | 1, 2, 3 | 310 | 350kcmil - 2/0 (Str) | 1 | #2 - #3 (Str) | 1 | 200 |
| 16371-_ | 1, 2, 3 | 310 | 350kcmil - 2/0 (Str) | 1 | #4 - #6 (Str) | 1 | 200 |
| 16372-_ | 1, 2, 3 | 310 | 350kcmil - 2/0 (Str) | 1 | #10 Cu/Al | 1 | 10 |
| 16373-_ | 1, 2, 3 | 310 | 350kcmil - 2/0 (Str) | 1 | #10 Cu/Al | 1 | 10 |
| 16325-_ | 1, 2, 3 | 350 | 2/0 - #1 (Str) | 1 | #4 - #6 (Str) | 1 | 10 |
| 16330-_ | 1, 2, 3 | 380 | 500kcmil - 4/0 (Str) | 1 | #2 - #3 (Str) | 1 | 10 |
| 16335-_ | 1, 2, 3 | 380 | 500kcmil - 4/0 (Str) | 1 | #2 - #3 (Str) | 1 | 10 |
| 16541-_ | 1, 2, 3 | 380 | 500kcmil - 4/0 (Str) | 1 | #6 Cu/Al (Str) | 1 | 10 |
| 16375-_ | 1, 2, 3 | 420 | 600kcmil - #2 (Str) | 1 | #4 - #6 (Str) | 1 | 10 |
| 16376-_ | 1, 2, 3 | 420 | 600kcmil - #2 (Str) | 1 | #2 - #3 (Str) | 1 | 10 |
| 16377-_ | 1, 2, 3 | 570 | 300kcmil - 2/0 (Str) | 1 | #4 - #6 (Str) | 1 | 10 |
| 16530-_ | 1, 2, 3 | 760 | 500kcmil - 4/0 (Str) | 1 | #4 - #6 (Str) | 1 | 10 |
| 16528-_ | 1, 2, 3 | 840 | 600kcmil - #2 (Str) | 1 | #4 - #6 (Str) | 1 | 10 |
| 16400 | 1, 2, 3 | 1520 | 500kcmil - 4/0 (Str) | 1 | #2 - #3 (Str) | 1 | 10 |
*Note: Wire size specifications for conductors are listed as AWG or kcmil. For stranded conductors, the use of ferrules requires a correctly sized UL Listed ferrule applied according to manufacturer specifications. Ferrule ratings apply to copper wire only. Torque values are in Nm (Lb-in). SCCR values are dependent on the application of an upstream current-limiting overcurrent protective device. See Short-Circuit Current Ratings table for specific fuse requirements.