hanxia HX DC044-2.0 TP
hanxia HX DC044-2.0 TP
Manufacturer:hanxia
Model Number:HX DC044-2.0 TP
Minimum Order Quantity:5
Standard Packaging:SMD
Delivery Time:1 working day
Product Details
Mounting Type:
Surface Mount, Right Angle
Connector Type:
DC Power Jack
Rated Current:
1A
Working Temperature:
-25℃~+70℃
Rated Voltage:
30V
Inside Contact Diameter:
2mm
Outside Contact Diameter:
6mm
Product Description
Detailed Specifications & Features
Product Overview
This document outlines the specifications for the Shenzhen Hanxia Electronic DC Jack, Model HX DC044-2.0 TP. It details electrical, mechanical, and environmental characteristics to ensure reliable performance in various applications.
Key Features:
- Designed for signal and power applications.
- Durable construction for extended use.
- Meets stringent electrical and mechanical performance standards.
Usage Conditions:
- Standard testing conditions: Temperature 5~35, Humidity 45~85%.
- Environmental operating range: Temperature -25 to +70.
Brand
Shenzhen Hanxia Electronic Co., Ltd.
Product Name
DC Jack
Part Number
HX DC044-2.0 TP
Origin
Shenzhen, China
| Specification Item | Test Condition | Specification |
|---|---|---|
| Electrical Characteristics | Rated Voltage | 30V DC |
| Rated Current | 1.0A | |
| Contact Resistance | 30m MAX | |
| Insulation Resistance | 100M Min | |
| Withstand Voltage | 500V AC | |
| Mechanical Performance | Mate Force | 3-20N |
| Unmate Force | 3-20N | |
| Durability | 5000 Cycles | |
| Temperature Range | Operating | -25~+70 |
| Contact Resistance | Measured at 1KHZ small current | 0.03 MAX |
| Insulation Resistance | DC500V potential for 1 minute (terminals & frame) | 100M Min |
| Withstand Voltage | AC500V (50/60Hz) for 1 minute (terminals & frame) | No breakdown |
| Insertion and Extraction Force | Measured by ergometer | 3-20N |
| Terminal Strength | 500gf static force for 1 minute | No mechanical or electrical damage |
| Soldering Test | Dipped 2mm in solder bath at 2305 for 3sec | N/A |
| Life Test | 5000 cycles at 20-30 cycles/min (unloading) | Contact resistance: 40m MAX; Drive force: within 30% of initial value |
| Heat Test | 48 hours at 802, then 30 min in normal condition | Contact resistance: 50m MAX; Insulation resistance: 100M Min; No damage |
| Humidity Test | 48 hours at 402, 90-95% RH, then 30 min in normal condition | No mechanical or electrical damage |
| Cold Test | 48 hours at -302, then 30 min in normal condition | No mechanical or electrical damage |