hanxia HX DC005-2.5-T
hanxia HX DC005-2.5-T
Manufacturer:hanxia
Model Number:HX DC005-2.5-T
Minimum Order Quantity:5
Standard Packaging:Through Hole
Delivery Time:1 working day
Product Details
Mounting Type:
Right Angle
Connector Type:
DC Power Jack
Rated Current:
3A
Working Temperature:
-25℃~+70℃
Inside Contact Diameter:
2.5mm
Rated Voltage:
30V
Outside Contact Diameter:
6.3mm
Product Description
Detailed Specifications & Features
Product Overview
This document outlines the specifications for the HX DC005-2.5-T DC Jack, manufactured by Shenzhen Hanxia Electronic Co., Ltd. It details electrical, mechanical, and environmental performance characteristics.
Brand
Shenzhen Hanxia Electronic Co., Ltd.
Origin
China
Part Number
HX DC005-2.5-T
Project
DC
Customer Approval
| Item | Specification | Test Condition | Requirement |
|---|---|---|---|
| Electrical Characteristics | Rated Voltage | 30V DC | |
| Electrical Characteristics | Rated Current | 3.0A | |
| Electrical Characteristics | Contact Resistance | Measured at 1KHz small current | 50m MAX (0.05 below) |
| Electrical Characteristics | Insulation Resistance | DC500V potential applied for 1 minute | 100M Min (100M above) |
| Electrical Characteristics | Withstand Voltage | AC500V (50/60Hz) for 1 minute | No breakdown |
| Mechanical Characteristics | Mate Force | 3-30N | |
| Mechanical Characteristics | Unmate Force | 3-30N | |
| Mechanical Characteristics | Durability | 5000 Cycles | |
| Environmental | Temperature Range | -25~+70 | |
| Soldering Test | Terminal dip in solder bath | 2305 for 3 sec, 2mm depth | |
| Durability Test | Cycles | 10-20 cycles per minute, no load | 5000 Cycles |
| Durability Test | Contact Resistance | 40m max | |
| Durability Test | Drive Force | Initial value | 30N |
| Heat Test | Condition | 802 for 48 hours, then 30 min in normal condition | Contact resistance 50m, Insulation resistance 100M, No mechanical/electrical damage |
| Humidity Test | Condition | 402, 90-95% RH for 48 hours, then 30 min in normal condition | No mechanical/electrical damage |
| Cold Test | Condition | -302 for 48 hours, then 30 min in normal condition | No mechanical/electrical damage |