<
>
JAE Electronics MX19004S51
JAE Electronics MX19004S51
Manufacturer:JAE Electronics
Model Number:MX19004S51
Minimum Order Quantity:1
Standard Packaging:-
Delivery Time:1 working day
Product Details
Pitch:
2.5mm
Number Of Rows:
1
Number Of Pins:
4P
Product Description
Detailed Specifications & Features
Product Information
This document details the crimping and contact withdrawal procedures for JAE connectors, specifically focusing on pin and socket contacts. It outlines the criteria for properly crimped contacts, applicable wires, stripping lengths, crimping applicators, and the process for withdrawing contacts from the housing.
Product Attributes
Brand
Japan Aviation Electronics Industry, Ltd. (JAE)
Division
Connector Division
Document Number
L No. JAHL-1594-E
Document Revision
DCF-C-091G (97. 10)
Copyright
2000, Japan Aviation Electronics Industry, Ltd.
Technical Specifications
| Wire Type | Conductor Cross-section [mm] | Applicable Wire Insulator [mm] | Crimp Height [mm] | Crimp Width (Ref.) [mm] | Crimp Height of Wire Insulator (Ref.) [mm] |
|---|---|---|---|---|---|
| CAVS0.3mm | 0.3717 | 1.4 ~1.5 | 0.73~0.83 | 1.48~1.54 | 1.6~1.7 |
| CPTL 22 | 0.3717 (Reference Information) | (Not Specified) | 0.73~0.83 | 1.48~1.54 | 1.7~1.9 |
| CAVS0.5 mm | 0.5630 | 1.6 ~1.7 | 0.75~0.85 | 1.52~1.58 | 1.7~1.9 |
| AVSS0.5 mm | 0.5630 | 1.6 ~1.7 | 0.75~0.85 | 1.52~1.58 | 1.7~1.9 |
Crimping Applicator
| Type | Product Name |
|---|---|
| Automatic Applicator | 350-MX19-3B |
| Semi-automatic Applicator | 350-MX19-2 |
Wire Stripping Length
| Contact Name | Length A [mm] |
|---|---|
| MX19P10K451 | 5 ~9 |
| MX19S10K451 | (Not Specified) |
Criteria for Proper Crimping
- Meet the specified crimp height.
- Include a Bell-mouth (no crimping on conductor).
- Conductor tip protrudes 0.5mm or less from the Conductor Barrel.
- All conductor strands are within the Conductor Barrel.
- Wire insulator is NOT crimped into the Conductor Barrel.
- No cracks or burrs in the crimping area.
Contact Withdrawal Notes
- Visual inspection for damage, deformation, or discoloration.
- Use a designated Withdrawing Tool (e.g., JAE's ET-MX19).
- Insert tool into the tool cavity, not the contact cavity.
- Release contact locking by meeting the molding lance with the tool.
- Withdraw wire on a straight axis; avoid snagging on grommets.
- Maximum withdrawal frequency per cavity is 3 times; replace if damaged.
- Do not apply unnecessary force.
Message for quick reply
Related Products