OMRON XG4 Series Flat Cable Connectors
The OMRON XG4 series offers mainstream circuit board connectors conforming to MIL standards with improved design. These connectors are designed for high-density mounting and offer advantages such as MIL-compliant cables for faster delivery and lower costs, and simplified patterning with a 2.54-mm pitch. They are suitable for various applications requiring reliable connections in compact spaces.
Key Features:
- Recommended for high-density mounting.
- MIL-compliant cable ensures faster delivery times and lower cost.
- 2.54-mm pitch simplifies patterning.
- Conform to MIL standards (MIL-C-83503).
- RoHS Compliant.
| Part Number (Plug) | Part Number (Socket) | No. of Contacts | No. of Polarity Slots | Description |
|---|---|---|---|---|
| XG4A-1079-A | XG4M-1031 | 10 | - | M 2-tier Plug |
| XG4A-1039-A | XG4M-1030 | 10 | - | M 2-tier Plug |
| XG4A-1439-A | XG4M-1430 | 14 | - | M 2-tier Plug |
| XG4A-1639-A | XG4M-1630 | 16 | - | M 2-tier Plug |
| XG4A-2039-A | XG4M-2030 | 20 | - | M 2-tier Plug |
| XG4A-2639-A | XG4M-2630 | 26 | - | M 2-tier Plug |
| XG4A-3039-A | XG4M-3030 | 30 | - | M 2-tier Plug |
| XG4A-3439-A | XG4M-3430 | 34 | - | M 2-tier Plug |
| XG4A-4039-A | XG4M-4030 | 40 | - | M 2-tier Plug |
| XG4A-5039-A | XG4M-5030 | 50 | - | M 2-tier Plug |
| XG4A-5079-A | XG4M-5031 | 50 | - | M 2-tier Plug |
| XG4A-6039-A | XG4M-6030 | 60 | - | M 2-tier Plug |
| XG4A-6079-A | XG4M-6031 | 60 | - | M 2-tier Plug |
| XG4A-6439-A | XG4M-6430 | 64 | - | M 2-tier Plug |
| XG4A-6479-A | XG4M-6431 | 64 | - | M 2-tier Plug |
| Part Number | Description | Rated Current | Rated Voltage | Contact Resistance | Insulation Resistance | Dielectric Strength | Total Insertion Force | Removal Force | Insertion Durability | Ambient Operating Temperature |
|---|---|---|---|---|---|---|---|---|---|---|
| XG4M (Socket) | MIL Sockets with strain relief (with lock) | 1 A | 250 VAC | 20 m max. (at 20 mV, 100 mA max.) | 1,000 M min. (at 500 VDC) | 500 VAC for 1 min (leakage current: 1 mA max.) | 1.96 N max. per contact | 0.39 N min. (with test gauge, t=0.64 mm) | 50 times | -55 to 105C (with no icing at low temperature) |
| XG4E (Plug) | Relay Plug | 1 A | 300 VAC | 20 m max. (at 20 mV, 100 mA max.) | 1,000 M min. (at 500 VDC) | 500 VAC for 1 min (leakage current: 1 mA max.) | 1.96 N max. per contact | 0.39 N min. (with test gauge, t=0.64 mm) | 50 times | -55 to 105C (with no icing at low temperature) |
| XG4A (Plug) | MIL Plugs | 3 A (See note 1) | 250 VAC | 20 m max. (at 20 mV, 100 mA max.) | 1,000 M min. (at 500 VDC) | 500 VAC for 1 min (leakage current: 1 mA max.) | 1.96 N max. per contact | 0.39 N min. (with test gauge, t=0.64 mm) | 50 times | -55 to 105C (with no icing at low temperature) |
| XG4C (Plug) | Box-type plugs | 3 A (See note 1) | 300 VAC | 20 m max. (at 20 mV, 100 mA max.) | 1,000 M min. (at 500 VDC) | 500 VAC for 1 min (leakage current: 1 mA max.) | 1.96 N max. per contact | 0.39 N min. (with test gauge, t=0.64 mm) | 50 times | -55 to 105C (with no icing at low temperature) |
Precautions
Correct Use
Mounting
- Be sure to anchor the board with screws before mounting.
- Note that a Polarizing Key cannot be mounted on the lower Plug.
Connecting the Socket
- Before connecting the XG4M with Strain Relief, remove as much slack from the cable as possible. Insert as shown below.
- Attach the Semi-cover before connecting the XG5M-N. It is not possible to use the Hood Cover.
Soldering
- Automated Soldering Conditions (Jet Flow)
1. Soldering temperature: 250 5C
2. Continuous soldering time: Within 51s - Solder-mount the XG4A with the lock levers fully closed or fully open. Solder-mounting the XG4A with the lock lever half-open may cause play in lock lever due to thermal deformation of the housing.
Lock Lever Operation
- When you operate the lock lever, do not force it past the movable range. The connector may be damaged.
- Do not use any type of tool to operate the lock lever. Operate it only with your hand. The connector may be damaged.
- Always release the lock mechanism before you disconnect the connector from the connected socket. The connector may be damaged.
Storage
- If the lock levers of the XG4A or XG4E connector are left at an intermediate position for a long time, they may get to feel loose in operation due to deterioration of the plastic part. When the lock levers are not used, store the plug with the lock levers fully closed or fully open.
Tools and Accessories (Sold Separately)
Polarity guides and slots can be used by themselves to help prevent reverse insertion. Use the Polarizing Key as well for best results.
Material: PBT resin (UL94 V-0/white)
The Coding Pin is used to prevent confusion when many Connectors with the same number of contacts are lined up. It can also be used to prevent reverse insertion when using Connectors without a shroud like the XG8 Unshrouded Plug. The Coding Pin can also be used with XC5 DIN Connectors as well as with XG5 Discrete-wire IDC Connectors.
Material: PBT resin (UL94 V-0)/white
Note: 1. A contact with a Coding Pin inserted cannot be used. 2. Each XG4Z-0005 has 4 Polarizing Keys.
The Contact Cutting Driver is used to cut (twist off) a contact on the mating Plug when using an XG4Z-0005 Coding Pin.
Use to lock Unshrouded Plugs (for XG8B and XG8W Plugs with right-angle terminals).
Material: Polyamide resin (UL94 V-2)/natural
Use to lock XG4C Box-type Plugs.
Material: Polyamide resin (UL94 V-2)/natural