OMRON XG4M-1030-T
XG4 Flat Cable Connectors
The XG4 series represents the mainstream of circuit board connectors, conforming to MIL standards with an improved design. These connectors offer enhanced reliability through a new production system and provide space-saving options like box-type plugs (XG4C) and IDC plugs (XG4E) suitable for relaying. A wide range of combinations can be achieved by integrating XG-5 IDC Connectors for discrete wires, XG8 Original Plugs, and XG2 IDC Connectors for PCBs. Lock levers are available for XG8 Original Plugs and XG4C Box-type Plugs for secure connections. All connectors conform to MIL-C-83503 standards.
- Advantages: Improved reliability, space-saving designs, versatile mating combinations, MIL standard compliance.
- Applications: Suitable for various circuit board connection needs where MIL standards are required.
Terminology
- MIL standard: Abbreviation for Military Standard, established in 1977 to unify compatibility and quality assurance conditions.
- Open-end cover: A cover allowing flat cable to be pulled out from both sides.
- Standoff: Part that lifts the housing from the board, improving airflow.
Brand
Brand
OMRON
Certifications
Certifications
MIL Standards (MIL-C-83503)
Applicable Wires
Applicable Wires
1.27-mm pitch flat cable incorporating AWG28 wires (UL2651, UL20012, UL20028)
Materials and Finish
Materials and Finish
Housings: Fiber-glass reinforced PBT resin (UL94 V-0)/black
Covers: Polyamide resin (UL94 V-0)/ black
Contacts (Mating end): Brass/nickel base, 0.15-m gold plating
Contacts (Terminal Press fit): Brass/nickel base, 2.0-m tin plating
Strain Reliefs: Polyamide resin (UL94 V-0)/ black
| Model | Appearance | Rated Current | Rated Voltage | Contact Resistance | Insulation Resistance | Dielectric Strength | Total Insertion Force | Removal Force | Insertion Durability | Ambient Operating Temperature |
|---|---|---|---|---|---|---|---|---|---|---|
| XG4M | MIL sockets with strain relief (with lock) | 1 A | 250 VAC | 20 m max. (at 20 mV, 100 mA max.) | 1,000 M min. (at 500 VDC) | 500 VAC for 1 min (leakage current: 1 mA max.) | 1.96 N max. per contact | 0.39 N min. (with test gauge, t= 0.64 mm) | 50 times | 55 to 105C (with no icing at low temperature) |
| XG4M-U | MIL sockets with strain relief | 1 A | 250 VAC | 20 m max. (at 20 mV, 100 mA max.) | 1,000 M min. (at 500 VDC) | 500 VAC for 1 min (leakage current: 1 mA max.) | 1.96 N max. per contact | 0.39 N min. (with test gauge, t= 0.64 mm) | 50 times | 55 to 105C (with no icing at low temperature) |
| XG4M | MIL plugs | 3 A (See note 1.) | 300 VAC | 20 m max. (at 20 mV, 100 mA max.) | 1,000 M min. (at 500 VDC) | 500 VAC for 1 min (leakage current: 1 mA max.) | 1.96 N max. per contact | 0.39 N min. (with test gauge, t= 0.64 mm) | 50 times | 55 to 105C (with no icing at low temperature) |
| XG4T | Plugs with dual ports | 3 A (See note 1.) | 300 VAC | 20 m max. (at 20 mV, 100 mA max.) | 1,000 M min. (at 500 VDC) | 500 VAC for 1 min (leakage current: 1 mA max.) | 1.96 N max. per contact | 0.39 N min. (with test gauge, t= 0.64 mm) | 50 times | 55 to 105C (with no icing at low temperature) |
| XG4A | IDC plugs with strain relief | 3 A (See note 1.) | 300 VAC | 20 m max. (at 20 mV, 100 mA max.) | 1,000 M min. (at 500 VDC) | 500 VAC for 1 min (leakage current: 1 mA max.) | 1.96 N max. per contact | 0.39 N min. (with test gauge, t= 0.64 mm) | 50 times | 55 to 105C (with no icing at low temperature) |
| XG4E | Box-type plugs | 3 A (See note 1.) | 300 VAC | 20 m max. (at 20 mV, 100 mA max.) | 1,000 M min. (at 500 VDC) | 500 VAC for 1 min (leakage current: 1 mA max.) | 1.96 N max. per contact | 0.39 N min. (with test gauge, t= 0.64 mm) | 50 times | 55 to 105C (with no icing at low temperature) |
| XG4S | Board-to-board sockets | 3 A (See note 1.) | 300 VAC | 20 m max. (at 20 mV, 100 mA max.) | 1,000 M min. (at 500 VDC) | 500 VAC for 1 min (leakage current: 1 mA max.) | 1.96 N max. per contact | 0.39 N min. (with test gauge, t= 0.64 mm) | 50 times | 55 to 105C (with no icing at low temperature) |
| XG4C | Box-type plugs | 3 A (See note 1.) | 300 VAC | 20 m max. (at 20 mV, 100 mA max.) | 1,000 M min. (at 500 VDC) | 500 VAC for 1 min (leakage current: 1 mA max.) | 1.96 N max. per contact | 0.39 N min. (with test gauge, t= 0.64 mm) | 50 times | 55 to 105C (with no icing at low temperature) |
| XG4H | Board-to-board sockets | 3 A (See note 1.) | 300 VAC | 20 m max. (at 20 mV, 100 mA max.) | 1,000 M min. (at 500 VDC) | 500 VAC for 1 min (leakage current: 1 mA max.) | 1.96 N max. per contact | 0.39 N min. (with test gauge, t= 0.64 mm) | 50 times | 55 to 105C (with no icing at low temperature) |
| No. of Contacts | Dimensions (mm) A | Dimensions (mm) B | Dimensions (mm) C | Dimensions (mm) D | Dimensions (mm) E | Dimensions (mm) F |
|---|---|---|---|---|---|---|
| 10 | 32.0 | 17.5 | 10.16 | 21.8 | 27.9 | 46.4 |
| 14 | 37.1 | 22.6 | 15.24 | 26.9 | 33.0 | 51.5 |
| 16 | 39.6 | 25.2 | 17.78 | 29.5 | 35.6 | 54.1 |
| 20 | 44.7 | 30.2 | 22.86 | 34.5 | 40.6 | 59.1 |
| 26 | 52.3 | 37.9 | 30.48 | 42.2 | 48.3 | 66.8 |
| 30 | 57.4 | 42.9 | 35.56 | 47.2 | 53.3 | 71.8 |
| 34 | 62.5 | 48.0 | 40.64 | 52.3 | 58.4 | 76.9 |
| 40 | 70.1 | 55.6 | 48.26 | 59.9 | 66.0 | 84.5 |
| 50 | 82.8 | 68.3 | 60.96 | 72.6 | 78.7 | 97.2 |
| 60 | 95.5 | 81.0 | 73.66 | 85.3 | 91.4 | 109.9 |
| 64 | 100.6 | 86.1 | 78.74 | 90.4 | 96.5 | 115.0 |
| No. of Contacts | Dimensions (mm) A | Dimensions (mm) B |
|---|---|---|
| 10 | 17.3 | 10.16 |
| 14 | 22.3 | 15.24 |
| 16 | 24.9 | 17.78 |
| 20 | 30.0 | 22.86 |
| 26 | 37.6 | 30.48 |
| 30 | 42.7 | 35.56 |
| 34 | 47.7 | 40.64 |
| 40 | 55.4 | 48.26 |
| 50 | 68.1 | 60.96 |
| 60 | 80.8 | 73.66 |
| 64 | 85.8 | 78.74 |