Product Details
Pins Structure: 2x5P
Contact Plating: Gold
Pitch: 2.54mm
Number Of PINs Per Row: 5
Number Of Rows: 2
Connector Type: IDC Header
Row Spacing: 2.54mm
Mounting Type: Right Angle
Product Description
Detailed Specifications & Features

OMRON XG4 Series Flat Cable Connectors

The OMRON XG4 series offers mainstream circuit board connectors conforming to MIL Standards with improved design. They are designed for high-density mounting and simplify pattern-making with a 2.54-mm pitch. The MIL-compliant cable ensures faster delivery times and lower costs compared to half-pitch board cables. These connectors are suitable for various applications requiring reliable and space-saving connections.

Key Features:

  • Recommended for high-density mounting.
  • MIL-compliant cable ensures faster delivery times and lower cost.
  • 2.54-mm pitch simplifies pattern-making.
  • Conform to MIL standards (MIL-C-83503).
  • RoHS Compliant.

Brand

OMRON

Series

XG4

Standard Compliance

MIL-C-83503

Certifications

RoHS Compliant

Polarity Slot Pitch

22.86 mm (Note 3)

Model Type No. of Contacts No. of Polarity Slots Description
XG4A-1079-A Plug 10 - M 2-tier Plug
XG4M-1031 Socket 10 - Socket for flat cable
XG4M-1030 Socket 10 - Socket for flat cable
XG4A-1039-A Plug 10 - M 2-tier Plug
XG4A-1439-A Plug 14 - M 2-tier Plug
XG4M-1430 Socket 14 - Socket for flat cable
XG4A-1639-A Plug 16 - M 2-tier Plug
XG4M-1630 Socket 16 - Socket for flat cable
XG4A-2039-A Plug 20 - M 2-tier Plug
XG4M-2030 Socket 20 - Socket for flat cable
XG4A-2639-A Plug 26 - M 2-tier Plug
XG4M-2630 Socket 26 - Socket for flat cable
XG4A-3039-A Plug 30 - M 2-tier Plug
XG4M-3030 Socket 30 - Socket for flat cable
XG4A-3439-A Plug 34 - M 2-tier Plug
XG4M-3430 Socket 34 - Socket for flat cable
XG4A-4039-A Plug 40 - M 2-tier Plug
XG4M-4030 Socket 40 - Socket for flat cable
XG4A-5039-A Plug 50 - M 2-tier Plug
XG4M-5030 Socket 50 - Socket for flat cable
XG4A-5079-A Plug 50 - M 2-tier Plug
XG4M-5031 Socket 50 - Socket for discrete wire
XG4A-6039-A Plug 60 - M 2-tier Plug
XG4M-6030 Socket 60 - Socket for flat cable
XG4A-6079-A Plug 60 - M 2-tier Plug
XG4M-6031 Socket 60 - Socket for discrete wire
XG4A-6439-A Plug 64 - M 2-tier Plug
XG4M-6430 Socket 64 - Socket for flat cable
XG4A-6479-A Plug 64 - M 2-tier Plug
XG4M-6431 Socket 64 - Socket for discrete wire
Specification Value
Rated Current 1 A (Note 1)
Rated Voltage 250 VAC / 300 VAC
Contact Resistance 20 m max. (at 20 mV, 100 mA max.)
Insulation Resistance 1,000 M min. (at 500 VDC)
Dielectric Strength 500 VAC for 1 min (leakage current: 1 mA max.)
Total Insertion Force 1.96 N max. per contact
Removal Force 0.39 N min. (with test gauge, t= 0.64 mm)
Insertion Durability 50 times
Ambient Operating Temperature -55 to 105C (with no icing at low temperature)

Precautions

Correct Use - Mounting
  • Be sure to anchor the board with screws before mounting.
  • Note that a Polarizing Key cannot be mounted on the lower Plug.
Correct Use - Connecting the Socket
  • Before connecting the XG4M with Strain Relief, remove as much slack from the cable as possible. Insert as shown below.
  • Attach the Semi-cover before connecting the XG5M-N. It is not possible to use the Hood Cover.
Correct Use - Soldering
  • Automated Soldering Conditions (Jet Flow):
  • Soldering temperature: 250 5C
  • Continuous soldering time: Within 51 s
Correct Use - Lock Lever Operation
  • When you operate the lock lever, do not force it past the movable range. The connector may be damaged.
  • Do not use any type of tool to operate the lock lever. Operate it only with your hand. The connector may be damaged.
  • Always release the lock mechanism before you disconnect the connector from the connected socket. The connector may be damaged.
Storage
  • If the lock levers of the XG4A or XG4E connector are left at an intermediate position for a long time, they may get to feel loose in operation due to deterioration of the plastic part. When the lock levers are not used, store the plug with the lock levers fully closed or fully open.

Tools and Accessories (Sold Separately)

XG4Z-0004 Polarizing Key

Polarity guides and slots can be used by themselves to help prevent reverse insertion. Use the Polarizing Key as well for best results. Material: PBT resin (UL94 V-O/white). Each XG4Z-0004 has 4 Polarizing Keys.

XG4Z-0005 Coding Pin

(To prevent erroneous insertion) The Coding Pin is used to prevent confusion when many Connectors with the same number of contacts are lined up. It can also be used to prevent reverse insertion when using Connectors without a shroud like the XG8 Unshrouded Plug. The Coding Pin can also be used with XC5 DIN Connectors as well as with XG5 Discrete-wire IDC Connectors. Material: PBT resin (UL94 V-0)/white. Note: 1. A contact with a Coding Pin inserted cannot be used. 2. Each XG4Z-0005 has 4 Coding Pins.

XY2E-0002 Contact Cutting Driver

The Contact Cutting Driver is used to cut (twist off) a contact on the mating Plug when using an XG4Z-0005 Coding Pin.

XG5Z-0002 Lock Lever for XG8B and XG8W Plugs (With Right-angle Terminals)

Use to lock Unshrouded Plugs (for XG8B and XG8W Plugs with right-angle terminals). Material: Polyamide resin (UL94 V-2)/natural.

XG4Z-0002 Lock Lever II for XG4C Plugs

Use to lock XG4C Box-type Plugs. Material: Polyamide resin (UL94 V-2)/natural.

Message for quick reply
Related Products