OMRON XG4A-3434
OMRON XG4 Series Flat Cable Connectors
The OMRON XG4 series offers mainstream circuit board connectors conforming to MIL Standards with improved design. These connectors are designed for high-density mounting and simplify pattern-making with their 2.54-mm pitch. They are compatible with various OMRON connector series for flexible system integration.
Key Features:
- Recommended for high-density mounting.
- MIL-compliant cable ensures faster delivery times and lower cost than half-pitch board cable.
- The 2.54-mm pitch simplifies pattern-making.
- Space-saving Box-type Plugs (XG4C) available.
- IDC Plugs (XG4E) can be used for relaying.
- An endless number of combinations can be made using the XG-5 IDC Connectors for discrete wires, XG8 Original Plugs, and the XG2 IDC Connectors for PCBs.
- The Original Plugs (XG8) and the Box-type Plugs (XG4C) can be locked using Lock Levers.
- Conform to MIL standards (MIL-C-83503).
Applications:
Suitable for various industrial and electronic applications requiring reliable and space-efficient connections.
Brand
OMRON
Series
XG4
Standards Compliance
MIL-C-83503
RoHS Compliant
Yes
| Model | Type | No. of Contacts | No. of Polarity Slots | Pitch | Cable Type |
|---|---|---|---|---|---|
| XG4A-1079-A | Plug | 10 | - | 2.54 mm | Flat Cable |
| XG4M-1031 | Socket | 10 | - | 2.54 mm | Flat Cable |
| XG4M-1030 | Socket | 10 | - | 2.54 mm | Flat Cable |
| XG4A-1039-A | Plug | 10 | - | 2.54 mm | Flat Cable |
| XG4A-1439-A | Plug | 14 | - | 2.54 mm | Flat Cable |
| XG4M-1430 | Socket | 14 | - | 2.54 mm | Flat Cable |
| XG4A-1639-A | Plug | 16 | - | 2.54 mm | Flat Cable |
| XG4M-1630 | Socket | 16 | - | 2.54 mm | Flat Cable |
| XG4A-2039-A | Plug | 20 | - | 2.54 mm | Flat Cable |
| XG4M-2030 | Socket | 20 | - | 2.54 mm | Flat Cable |
| XG4A-2639-A | Plug | 26 | - | 2.54 mm | Flat Cable |
| XG4M-2630 | Socket | 26 | - | 2.54 mm | Flat Cable |
| XG4A-3039-A | Plug | 30 | - | 2.54 mm | Flat Cable |
| XG4M-3030 | Socket | 30 | - | 2.54 mm | Flat Cable |
| XG4A-3439-A | Plug | 34 | - | 2.54 mm | Flat Cable |
| XG4M-3430 | Socket | 34 | - | 2.54 mm | Flat Cable |
| XG4A-4039-A | Plug | 40 | - | 2.54 mm | Flat Cable |
| XG4M-4030 | Socket | 40 | - | 2.54 mm | Flat Cable |
| XG4A-5039-A | Plug | 50 | - | 2.54 mm | Flat Cable |
| XG4M-5030 | Socket | 50 | - | 2.54 mm | Flat Cable |
| XG4A-5079-A | Plug | 50 | - | 2.54 mm | Flat Cable |
| XG4M-5031 | Socket | 50 | - | 2.54 mm | Flat Cable |
| XG4A-6039-A | Plug | 60 | - | 2.54 mm | Flat Cable |
| XG4M-6030 | Socket | 60 | - | 2.54 mm | Flat Cable |
| XG4A-6079-A | Plug | 60 | - | 2.54 mm | Flat Cable |
| XG4M-6031 | Socket | 60 | - | 2.54 mm | Flat Cable |
| XG4A-6439-A | Plug | 64 | - | 2.54 mm | Flat Cable |
| XG4M-6430 | Socket | 64 | - | 2.54 mm | Flat Cable |
| XG4A-6479-A | Plug | 64 | - | 2.54 mm | Flat Cable |
| XG4M-6431 | Socket | 64 | - | 2.54 mm | Flat Cable |
| XG5M-1031 | Socket | 10 | - | 2.54 mm | Discrete Wire |
| XG5M-1431 | Socket | 14 | - | 2.54 mm | Discrete Wire |
| XG5M-1631 | Socket | 16 | - | 2.54 mm | Discrete Wire |
| XG5M-2031 | Socket | 20 | - | 2.54 mm | Discrete Wire |
| XG5M-2631 | Socket | 26 | - | 2.54 mm | Discrete Wire |
| XG5M-3031 | Socket | 30 | - | 2.54 mm | Discrete Wire |
| XG5M-3431 | Socket | 34 | - | 2.54 mm | Discrete Wire |
| XG5M-4031 | Socket | 40 | - | 2.54 mm | Discrete Wire |
| XG5M-5031 | Socket | 50 | - | 2.54 mm | Discrete Wire |
| XG5M-6031 | Socket | 60 | - | 2.54 mm | Discrete Wire |
| XG5M-6431 | Socket | 64 | - | 2.54 mm | Discrete Wire |
| Specification | Value |
|---|---|
| Rated Current | 1 A (e.g., XG4M) |
| Rated Voltage | 250 VAC / 300 VAC |
| Contact Resistance | 20 m max. (at 20 mV, 100 mA max.) |
| Insulation Resistance | 1,000 M min. (at 500 VDC) |
| Dielectric Strength | 500 VAC for 1 min (leakage current: 1 mA max.) |
| Total Insertion Force | 1.96 N max. per contact |
| Removal Force | 0.39 N min. (with test gauge, t= 0.64 mm) |
| Insertion Durability | 50 times |
| Ambient Operating Temperature | -55 to 105C (with no icing at low temperature) |
| Accessory | Description | Material | Notes |
|---|---|---|---|
| XG4Z-0004 Polarizing Key | Prevents reverse insertion. | PBT resin (UL94 V-0/white) | Each pack has 4 keys. |
| XG4Z-0005 Coding Pin | Prevents confusion and reverse insertion. | PBT resin (UL94 V-0)/white | A contact with a Coding Pin inserted cannot be used. Each pack has 4 pins. |
| XY2E-0002 Contact Cutting Driver | Cuts (twists off) a contact for use with Coding Pins. | - | - |
| XG5Z-0002 Lock Lever | Locks Unshrouded Plugs (XG8B and XG8W with right-angle terminals). | Polyamide resin (UL94 V-2)/natural | - |
| XG4Z-0002 Lock Lever II | Locks XG4C Box-type Plugs. | Polyamide resin (UL94 V-2)/natural | - |
Precautions
Correct Use
- Mounting: Be sure to anchor the board with screws before mounting. A Polarizing Key cannot be mounted on the lower Plug.
- Connecting the Socket: Before connecting the XG4M with Strain Relief, remove as much slack from the cable as possible. Attach the Semi-cover before connecting the XG5M-N; the Hood Cover cannot be used.
- Lock Lever Operation: Do not force the lock lever past its movable range. Do not use tools to operate the lock lever; use only your hand. Always release the lock mechanism before disconnecting the connector.
Soldering
- Automated Soldering Conditions (Jet Flow): Soldering temperature: 250 5C; Continuous soldering time: Within 51 s.
- Solder-mounting XG4A: Ensure lock levers are fully closed or fully open. Half-open lock levers may cause play due to thermal deformation.
Storage
- If lock levers of XG4A or XG4E are left in an intermediate position for a long time, they may become loose due to plastic part deterioration. Store with lock levers fully closed or fully open when not in use.