HRS DF3-10EP-2C
Product Overview
This product is a connector designed for use with specific contact parts and cables, offering reliable electrical performance within a defined operating temperature range. It is suitable for applications requiring AC voltage and current handling capabilities, with different ratings based on wire gauge.
Product Attributes
- Brand: HIROSE ELECTRIC CO., LTD.
- Applicable Contact: DF3-EP2428PCF(A), DF3-EP2428PC(A)
- Applicable Connector: DF3-*S-2C
- Applicable Cable: UL1061, UL1007 AWG24 to 28
- Certifications: UL, CSA
- Code No.: CL543
- Drawing No.: ELC-162330-00-01
- Part No.: DF3-*EP-2C
- Copyright: 2024 HIROSE ELECTRIC CO., LTD.
Technical Specifications
| Item | Test Method | Requirements | QT | AT |
| Rating | Operating temperature range | -30C to +85C (Note 1) | X | |
| Rating | Storage temperature range | -10C to +60C | X | |
| Rating | Voltage | 250V AC | X | |
| Rating | ULCSA Rating Voltage | 30V AC | X | |
| Rating | Current AWG 24 | 3A | X | |
| Rating | Current AWG 26 | 2A | X | |
| Rating | Current AWG 28 | 1A | X | |
| Construction | General examination | According to drawing. | X | X |
| Construction | Marking | Confirmed visually. | X | X |
| Electric characteristics | Insulation resistance | 500V DC. 1000M MIN. | X | |
| Electric characteristics | Voltage proof | 650V AC for 1 min. No flashover or breakdown. | X | |
| Mechanical characteristics | Vibration | Frequency 10 to 55 Hz, single amplitude 0.75 mm, at 2 h, for 3 directions. No electrical discontinuity of 1s. No damage, crack or looseness of parts. | X | |
| Mechanical characteristics | Shock | 490 m/s duration of pulse 11 ms at 3 times for 3 directions. | X | |
| Environmental characteristics | Rapid change of temperature | Temperature -55 5 to 35+85 5 to 35 C Time 30 5 to 15 30 5 to 15 min Under 5 cycles. Insulation resistance: 1000M MIN. No damage, crack or looseness of parts. | X | |
| Environmental characteristics | Damp heat (Steady state) | Exposed at 40 2 C, 90 to 95 %, 96 h. Insulation resistance: 1000M MIN. No damage, crack or looseness of parts. | X |
Note 1: Including the temperature rise by current.
Note: Unless otherwise specified, refer to IEC 60512.
Note: QT: Qualification Test, AT: Assurance Test, X: Applicable Test
Remarks: In case of consideration for using Automotive equipment / device which demand high reliability, kindly contact our sales window correspondents.