HRS DF3AA-15EP-2C
Product Overview
This product is a cable designed for high reliability applications, including automotive equipment. It supports specific contact parts and connectors, and is available in AWG 24, 26, and 28 gauges with corresponding current ratings. The product is built to withstand a wide operating temperature range and meets stringent electrical, mechanical, and environmental testing standards.
Product Attributes
- Brand: Hirose Electric Co., Ltd.
- Applicable Contact: DF3-EP2428PCF(A), DF3-EP2428PC(A)
- Applicable Connector: DF3-*S-2C
- Applicable Cable: UL1061, 1007 AWG24 to 28
- Certifications: UL, CSA
Technical Specifications
| Item | Test Method | Requirements | QT | AT |
|---|---|---|---|---|
| Rating | Operating temperature range | -30C to +85C (Note 1) | X | X |
| Rating | Storage temperature range | -10C to +60C | X | X |
| Rating | Voltage | 250V AC (ULCSA Rating) | X | X |
| Rating | Voltage | 30V AC | X | X |
| Rating | Current (AWG 24) | 3A | X | X |
| Rating | Current (AWG 26) | 2A | X | X |
| Rating | Current (AWG 28) | 1A | X | X |
| Construction | General examination | According to drawing. | X | X |
| Construction | Marking | Confirmed visually. | X | X |
| Electric characteristics | Insulation resistance | 500V DC. 1000M MIN. | X | |
| Electric characteristics | Voltage proof | 650V AC for 1 min. No flashover or breakdown. | X | |
| Mechanical characteristics | Vibration | Frequency 10 to 55 Hz, single amplitude 0.75 mm, at 2 h, for 3 directions. No electrical discontinuity of 1s. No damage, crack or looseness of parts. | X | |
| Mechanical characteristics | Shock | 490 m/s duration of pulse 11 ms at 3 times for 3 directions. | X | |
| Environmental characteristics | Rapid change of temperature | Temperature -555 to 35+855 to 35 C Time 305 to 15 305 to 15 min Under 5 cycles. Insulation resistance: 1000M MIN. No damage, crack or looseness of parts. | X | |
| Environmental characteristics | Damp heat (Steady state) | Exposed at 40 2 C, 90 to 95 , 96 h. Insulation resistance: 1000M MIN. No damage, crack or looseness of parts. | X |
Note 1: Including the temperature rise by current. Unless otherwise specified, refer to IEC 60512.