Harwin M80-5100842
Harwin M80-5100842
Manufacturer:Harwin
Model Number:M80-5100842
Minimum Order Quantity:1
Standard Packaging:Through Hole
Delivery Time:1 working day
Product Details
Flame Retardant Rating:
UL94V-0
Contact Plating:
Tin
Pitch:
2mm
Contact Material:
Phosphor Bronze
Voltage Rating (Max):
800V
Number Of Rows:
2
Operating Temperature:
-55℃~+125℃
Row Spacing:
2mm
Mounting Type:
Through Hole
Product Description
Detailed Specifications & Features
Product Overview
The M80 & M83 Series Rectangular Connectors are designed for robust performance in demanding environments. They offer reliable electrical connections with a focus on environmental resistance, vibration and shock survivability, and mechanical integrity. These connectors are suitable for applications requiring high reliability under challenging conditions.
Environmental Classification 55/125/56 Days at 95% RH
Salt Spray (SRS BS2011 Part 2.1Kb) 5% Solution, 6.5/7.2pH @ 40C, 93% Humidity for 66 hours
Salt Spray (EIA364 Test Procedure 26 Condition A) 5% Solution, 6.5/7.2pH @ 35C, 95% Humidity for 96 hours
| Specification | Value |
|---|---|
| Operating Temperature Range | -55C to +125C |
| Low Air Pressure Severity (electrically loaded) | 300 mbar (9,144m/30,000ft) |
| High Temperature, Long Term (current 8s in 2.7.1.) | 1,000 hours at 85C |
| High Temperature, Short Term (no electrical load) | 250 hours at 125C |
| Contact Wipe (T-Contact) | 2.00mm min |
| Contact Type | Vibration Severity | Shock Severity | Bump Severity |
|---|---|---|---|
| Standard Signal Contact | 10Hz to 2,000Hz, 0.75mm, 98m/s (10G), duration 6 hours | 981m/s (100G), 18 shocks total | 390m/s (40G), 4,000+10 bumps |
| Standard Signal Contact (20G test) | 10Hz to 81.73Hz, 1.5mm peak-to-peak; 57.55Hz to 2,000Hz, 196.2m/s (20G), duration 2 hours | ||
| T-Contact | 10Hz to 13.6Hz, 35mm peak-to-peak, 13.6Hz to 41.6Hz, 1.5mm peak-to-peak, 41.6Hz to 2,000Hz, 392.4m/s (40G), duration 6 hours | 981m/s (100G) |
| Specification | M80 Standard Signal Contact | M83 Signal Contact | T-Contact |
|---|---|---|---|
| Clip Retention in Body | 18N min | ||
| Contact Retention in Housing | 10N min | ||
| Contact Replacement in Housing (Male Crimp JACKSCrew) | 2 operations at 10N | ||
| Durability | 500 operations | 1,000 operations | |
| Contact Holding Force | 0.2N min | ||
| Insertion Force (per contact, max) | 2.0N max | 1.0N max | 4.0N max |
| Withdrawal Force (per contact, min) | 0.2N min | 0.2N min | 0.5N min |
| Cable Contact Replacement in Housing | up to 2 times max |
| Specification | Value |
|---|---|
| Recommended Wire Type | See Component Specification CO49XX (latest issue) |
| Coax Contact Impedance | 50 |
| Coax Contact Voltage Rating (at 1,013mbar) | 180V AC at 500mA |
| Coax Contact Voltage Proof (at 1,013mbar) | 1,000V ACrms |
| Coax Contact Resistance | 6m max |
| Coax Contact Insulation Resistance (at 250V RMS) | 10 M |
| Coax Contact Durability | 500 operations |
| Coax Contact Insertion Force (per contact, max) | 20.0N max |
| Coax Contact Withdrawal Force (per contact, min) | 0.5N min |
| Coax Contact Wipe | 1.30mm min |
| Coax Contact Replacement in Housing | 5 times max |